Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Anal Toxicol ; 46(9): 1045-1052, 2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-35022735

RESUMO

This manuscript reported a fast and rapid qualitative screening method for abuse drugs in urine by liquid chromatography-tandem mass spectrometry (LC-MS-MS). The scope of the abuse drugs under investigation included methamphetamine (MA), amphetamine (AMP), methylenedioxymethamphetamine (MDMA), methylenedioxyamphetamine (MDA), paramethoxymethamphetamine (PMMA), ephedrine, pseudoephedrine, ketamine (KET), deschloroketamine (DCK), 2-fluorodeschloroketamine (2 F-DCK) and deschloro-N-ethylketamine (2-oxo-PCE). The method employed a dual mode extraction (DME) column as a novel clean-up method for the urine matrix. To an aliquot of 0.2 mL urine, internal standards (ISTDs) and 0.4 mL of acidified methanol were added. After vortex and centrifugation, the supernatant was passed through a DME column before LC-MS-MS analysis. Chromatographic separation was achieved with a C18 column by gradient elution. The limits of detection (LODs) for MA, AMP, MDMA, MDA and PMMA were 3 ng/mL, whereas those for ephedrine and pseudoephedrine were 10 ng/mL and those for KET, DCK, 2 F-DCK and 2-oxo-PCE were 1 ng/mL. The matrix effects ranged from -12% to 7% (%CV from 4% to 19%). This method is fit for the intended purpose for forensic toxicology, as well as for forensic analysis of drugs facilitating sexual assault and other criminal acts.


Assuntos
3,4-Metilenodioxianfetamina , Drogas Ilícitas , Ketamina , N-Metil-3,4-Metilenodioxianfetamina , Transtornos Relacionados ao Uso de Substâncias , Humanos , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Efedrina , Polimetil Metacrilato/análise , Pseudoefedrina , Detecção do Abuso de Substâncias/métodos , 3,4-Metilenodioxianfetamina/urina , Anfetamina/urina
2.
Environ Sci Technol ; 56(12): 8255-8265, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35652387

RESUMO

Although nanoplastics (NPs) are recognized as emerging anthropogenic particulate pollutants, the occurrence of NPs in the environment is rarely reported, partly due to the lack of sensitive methods for the concentration and detection of NPs. Herein, we present an efficient method for enriching NPs of different compositions and various sizes. Alkylated ferroferric oxide (Fe3O4) particles were prepared as adsorbents for highly efficient capture of NPs in environmental waters, and the formed large Fe3O4-NP agglomerates were separated by membrane filtration. Detection limits of 0.02-0.03 µg/L were obtained for polystyrene (PS) and poly(methyl methacrylate) (PMMA) NPs by detection with pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS). When analyzing real water samples from different sources, it is remarkable that PS NPs were detected in 11 out of 15 samples with concentrations ranging from <0.07 to 0.73 µg/L, while PMMA were not detected. The wide detection of PS NPs in our study confirms the previous speculation that NPs may be ubiquitous in the environmental waters. The accurate quantification of PS NPs in environmental waters make it possible to monitor the pollution status of NPs in aquatic systems and evaluate their potential risks.


Assuntos
Nanopartículas , Poluentes Químicos da Água , Cromatografia Gasosa-Espectrometria de Massas , Nanopartículas/química , Óxidos , Polimetil Metacrilato/análise , Poliestirenos , Pirólise , Poluentes Químicos da Água/química
3.
Environ Sci Technol ; 56(8): 4988-4997, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35373559

RESUMO

Nanoplastics (NPs) are currently considered an environmental pollutant of concern, but the actual extent of NP pollution in environmental water bodies remains unclear and there is not enough quantitative data to conduct proper risk assessments. In this study, a pretreatment method combining ultrafiltration (UF, 100 kDa) with hydrogen peroxide digestion and subsequent detection with pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) was developed and used to identify and quantify six selected NPs in surface water (SW) and groundwater (GW), including poly(vinylchloride) (PVC), poly(methyl methacrylate) (PMMA), polypropylene (PP), polystyrene (PS), polyethylene (PE), and poly(ethylene terephthalate) (PET). The results show that the proposed method could detect NPs in environmental water samples. Nearly all selected NPs could be detected in the surface water at all locations, while PVC, PMMA, PS, and PET NPs were frequently below the detection limit in the groundwater. PP (32.9-69.9%) and PE (21.3-44.3%) NPs were the dominant components in both surface water and groundwater, although there were significant differences in the pollution levels attributed to the filtration efficiency of riverbank, with total mass concentrations of 0.283-0.793 µg/L (SW) and 0.021-0.203 µg/L (GW). Overall, this study quantified the NPs in complex aquatic environments for the first time, filling in gaps in our knowledge about NP pollution levels and providing a useful methodology and important reference data for future research.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Cromatografia Gasosa-Espectrometria de Massas , Microplásticos , Plásticos/análise , Polietileno/análise , Polimetil Metacrilato/análise , Polipropilenos/análise , Poliestirenos , Cloreto de Polivinila , Pirólise , Água , Poluentes Químicos da Água/química
4.
Sci Total Environ ; 825: 154015, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35189238

RESUMO

The increasing amount of plastic waste has raised concerns about microplastics (MPs) in aquatic environments. MPs can be fragmented into nanoplastics that can pass through water treatment processes and into tap water; potentially threatening human health because of their high adsorption capacity for hazardous organic materials and their intrinsic toxicity. This case study investigates the identification, fate, and removal efficiency of MPs in Korean drinking water treatment plants. Two sites on the Nakdong River, two lake reservoirs (raw water sources), and four corresponding drinking water treatment plants were targeted to trace the amounts, types, and sizes of MPs throughout the treatment process. Monthly quantitative and qualitative analyses were conducted by chemical image mapping using micro-Fourier-transform infrared spectroscopy. MPs larger than 20 µm were detected, and their sizes and types were quantified using siMPle software. Overall, the number of MPs in the river sites (January to April and October to November) exceeded those in the reservoirs, but only slight differences in the number of MPs between rivers and lake reservoirs were detected from June to October. The annual average number of MPs in River A, B and Lack C and D was not distinctively different (2.65, 2.48, 2.46 and 1.87 particles/L, respectively). The majority of MPs found in raw waters were polyethylene (PE)/polypropylene (PP) (> 60%) and polyethylene terephthalate (PET)/poly(methyl methacrylate) (PMMA) (20%), in addition to polyamide (<10%) in the river and polystyrene (<10%) in the lake reservoirs. Approximately 70-80% of the MPs were removed by pre-ozonation/sedimentation; 81-88% of PE/PP was removed by this process. PET/PMMA was removed by filtration. Correlation of MPs with water quality parameters showed that the Mn concentration was moderately correlated with the MP abundance in rivers and lake reservoirs, excluding the lake with the lowest Mn concentration, while the total organic carbon was negatively correlated with the MP abundance in both rivers (A and B) and lake reservoir C.


Assuntos
Água Potável , Poluentes Químicos da Água , Purificação da Água , Água Potável/análise , Monitoramento Ambiental , Humanos , Microplásticos , Plásticos/análise , Polietileno/análise , Polimetil Metacrilato/análise , Polipropilenos/análise , Poluentes Químicos da Água/análise
5.
Colloids Surf B Biointerfaces ; 183: 110406, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31401462

RESUMO

Amphotericin B is used for local delivery from polymethylmethacrylate to treat fungal prosthetic joint infections. The optimal amphotericin B formulation and the influence of different poragens in the bone cements are unknown. To investigate the necessary amount of amphotericin B in the bone cement to prevent Candida biofilm several amphotericin B formulations were studied: non-liposomal and liposomal with or without poragen gentamicin. For the non-liposomal formulation, standard bile salt, the sodium deoxycholate, was used and additionally N-methyl-D-glucamine/palmitate was applied. The activity of the released amphotericin B was tested against C. albicans, C. glabrata, C. parapsilosis and C. krusei biofilms with application of the isothermal calorimeter and standard microbiological methods. Compressive strength was measured before and after antifungal elution from the cements. There is less aggregated N-methyl-D-glucamine/palmitate amphotericin B released but its antifungal activity is equivalent with the deoxycholate amphotericin B. The minimum quantity of antifungal preventing the Candida biofilm formation is 12.5 mg in gram of polymer powder for both non-liposomal formulations. The addition of gentamicin reduced the release of sodium deoxycholate amphotericin B. Gentamicin can be added to N-methyl-D-glucamine/palmitate amphotericin B in order to boost the antifungal release. When using liposomal amphotericin B more drug is released. All amphotericin B formulations were active against Candida biofilms. Although compressive strength slightly decreased, the obtained values were above the level of strength recommended for the implant fixation. The finding of this work might be beneficial for the treatment of the prosthetic joint infections caused by Candida spp.


Assuntos
Anfotericina B/análogos & derivados , Anfotericina B/farmacologia , Antifúngicos/farmacologia , Biofilmes/efeitos dos fármacos , Candida albicans/efeitos dos fármacos , Ácido Desoxicólico/farmacologia , Anfotericina B/química , Antifúngicos/química , Biofilmes/crescimento & desenvolvimento , Cimentos Ósseos/análise , Cimentos Ósseos/química , Candida albicans/crescimento & desenvolvimento , Candida glabrata/efeitos dos fármacos , Candida glabrata/crescimento & desenvolvimento , Candida parapsilosis/efeitos dos fármacos , Candida parapsilosis/crescimento & desenvolvimento , Força Compressiva , Ácido Desoxicólico/química , Combinação de Medicamentos , Liberação Controlada de Fármacos , Gentamicinas/farmacologia , Cinética , Teste de Materiais , Testes de Sensibilidade Microbiana , Polimetil Metacrilato/análise , Polimetil Metacrilato/química , Porosidade
6.
Rev. bras. cir. plást ; 34(1): 156-162, jan.-mar. 2019. ilus
Artigo em Inglês, Português | LILACS | ID: biblio-994624

RESUMO

Introdução: Os preenchedores permanentes, apesar de resultados duradouros, são verdadeiros problemas quando causam complicações. No Brasil, o PMMA é um produto aprovado pela Anvisa, mas seu uso extrapola suas indicações, levando a complicações graves. Há mais de uma década, existem recomendações sobre sua restrição, mas casos com consequências graves do seu uso irresponsável são atuais. Objetivo: Relatar complicação grave do uso irregular do PMMA e discutir a realidade brasileira atual baseado em determinações das entidades médicas, assim como dos órgãos reguladores. Métodos: É relatado um caso de necrose extensa da região glútea após a injeção de PMMA por profissional não qualificado e discutida a situação brasileira atual do produto com base nas entidades médicas e revisão da literatura do Brasil. Discussão: Apesar do esforço das entidades médicas, são inúmeros os casos de complicações agudas e crônicas relatados na literatura brasileira. No ano de 2016, foram registradas mais de 17 mil complicações relacionadas ao PMMA, mesmo assim, é difícil estabelecer dados epidemiológicos confiáveis, pois não há controle do número de aplicações, da qualidade do produto utilizado e da capacitação dos profissionais que o utilizam. Conclusão: No Brasil, há um número expressivo de procedimentos reparadores para correção de complicações decorrentes do uso do PMMA. A gravidade do caso relatado traz à tona a necessidade de combate à má prática por profissionais não capacitados, assim como um controle mais rigoroso da comercialização do produto por entidades reguladoras.(AU)


Introduction: Use of permanent fillers can lead to significant complications. In Brazil, polymethylmethacrylate (PMMA) is a product approved by the Agência Nacional de Vigilância Sanitária (ANVISA), but its use exceeds its indications, leading to serious complications. Recommendations for restricted use have been in place for more than a decade, but cases with serious consequences due to inappropriate use are still seen. Objective: To report a serious complication due to inappropriate use of PMMA and discuss the current status of PMMA use in Brazil based on recommendations of medical societies and regulatory agencies. Methods: This report describes a case of extensive necrosis of the gluteal region after injection of PMMA by a non-qualified practitioner; the report also reviews the literature on the current status of PMMA use in Brazil. Discussion: Despite the efforts of medical societies, acute and chronic complications are still reported in the Brazilian literature. In 2016, more than 17,000 PMMArelated complications were reported; nevertheless, reliable epidemiological data remain unavailable because the number of treatments, the quality of the product, and the training of practitioners remain unregulated. Conclusion: A significant number of repair procedures are performed in Brazil to correct complications resulting from the use of PMMA. The severity of the reported case highlights the need to combat bad practice by untrained professionals, as well as the need for greater control of PMMA marketing by regulatory agencies.(AU)


Assuntos
Humanos , Feminino , Adulto , Polimetil Metacrilato/análise , Polimetil Metacrilato/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Necrose/diagnóstico
7.
J Orthop Surg (Hong Kong) ; 27(1): 2309499018822247, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30798727

RESUMO

PURPOSE: Bone cement is commonly used as a void filler for bone defects. Antibiotics can be added to bone cement to increase local drug delivery in eradicating infection. After antibiotic elution, nonbiodegradable material becomes an undesirable agent. The purpose of this study was to evaluate effects of addition of vancomycin on the compressive strength of injectable synthetic bone substitute, JectOS®. JectOS, a partially biodegradable cement that over time dissolves and is replaced by bone, could be potentially used as a biodegradable antibiotic carrier. METHODS: Vancomycin at various concentrations was added to JectOS and polymethyl methacrylate (PMMA). Then, the cement was molded into standardized dimensions for in vitro testing. Cylindrical vancomycin-JectOS samples were subjected to compressive strength. The results obtained were compared to PMMA-vancomycin compressive strength data attained from historical controls. The zone of inhibition was carried out using vancomycin-JectOS and vancomycin-PMMA disk on methicillin-resistant strain culture agar. RESULTS: With the addition of 2.5%, 5%, and 10% vancomycin, the average compressive strengths reduced to 8.01 ± 0.95 MPa (24.6%), 7.52 ± 0.71 MPa (29.2%), and 7.23 ± 1.34 MPa (31.9%). Addition of vancomycin significantly weakened biomechanical properties of JectOS, but there was no significant difference in the compressive strength at increasing concentrations. The average diameters of zone of inhibition for JectOS-vancomycin were 24.7 ± 1.44 (2.5%) mm, 25.9 ± 0.85 mm (5%), and 26.8 ± 1.81 mm (10%), which outperformed PMMA. CONCLUSION: JectOS has poor mechanical performance but superior elution property. JectOS-vancomycin cement is suitable as a void filler delivering high local concentration of vancomycin. We recommended using it for contained bone defects that do not require mechanical strength.


Assuntos
Cimentos Ósseos/química , Teste de Materiais/métodos , Polimetil Metacrilato/análise , Vancomicina/análise , Antibacterianos/análise , Força Compressiva , Humanos
8.
Anal Chem ; 91(3): 1785-1790, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30588801

RESUMO

The contamination of micro- and nanoplastics in marine systems and freshwater is a global issue. Determination of micro- and nanoplastics in the aqueous environment is of high priority to fully assess the risk that plastic particles will pose. Although microplastics have been detected in a variety of aquatic ecosystems, the analysis of nanoplastics remains an unsolved challenge. Herein, for the first time, a Triton X-45 (TX-45)-based cloud-point extraction (CPE) was proposed to preconcentrate trace nanoplastics in environmental waters. Under the optimum extraction conditions, an enrichment factor of 500 was obtained for two types of nanoplastics with different compositions, polystyrene (PS) and poly(methyl methacrylate) (PMMA), without disturbing their original morphology and sizes. Additionally, following thermal treatment at 190 °C for 3 h, the CPE-obtained extract could be submitted to pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) analysis for mass quantification of nanoplastics. Taking 66.2 nm PS nanoplastics and 86.2 nm PMMA nanoplastics as examples, the proposed method showed excellent reproducibility, and high sensitivity with respective detection limits of 11.5 and 2.5 fM. Feasibility of the proposed approach was verified by application of the optimized procedure to four real water samples. Recoveries of 84.6-96.6% at a spiked level of 88.6 fM for PS nanoplastics and 76.5-96.6% at a spiked level of 50.4 fM for PMMA nanoplastics were obtained. Consequently, this work provides an efficient approach for nanoplastic analysis in environmental waters.


Assuntos
Extração Líquido-Líquido/métodos , Nanopartículas/análise , Polimetil Metacrilato/análise , Poliestirenos/análise , Pirólise , Dissacarídeos , Glucuronatos , Limite de Detecção , Nanopartículas/química , Octoxinol/química , Polimetil Metacrilato/química , Poliestirenos/química , Reprodutibilidade dos Testes , Rios/química , Água do Mar/análise , Tensoativos/química , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química
9.
Environ Pollut ; 244: 766-773, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30388680

RESUMO

Reported here is the first evidence of plastic ingestion by freshwater fishes in the Amazon. Plastic bags, bottles, fishing gear, and other products are entering Amazonian water bodies and degrade into meso- and micro-plastic particles that may be ingested, either directly or indirectly via food chains, by fishes. Examination of stomach contents from 172 specimens of 16 serrasalmid species from lower Xingu River Basin revealed consumption of plastic particles by fishes in each of three trophic guilds (herbivores, omnivores, carnivores). Overall, about one quarter of specimens and 80% of species analyzed had ingested plastic particles ranging from 1 to 15 mm in length. Fourier transform infrared spectroscopy indicated 12 polymer types, including 27% identified as polyethylene, 13% polyvinyl chloride, 13% polyamide, 13% polypropylene, 7% poly(methyl methacrylate), 7% rayon, 7% polyethylene terephtalate, and 13% a blend of polyamide and polyethylene terephtalate. Dimensions of ingested plastic particles varied among trophic guilds, even though the frequency and mass of ingested particles were not significantly different among fishes with different feeding habits.


Assuntos
Caraciformes/fisiologia , Monitoramento Ambiental/métodos , Conteúdo Gastrointestinal/química , Plásticos/análise , Plásticos/toxicidade , Resíduos/análise , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade , Animais , Celulose/análise , Ingestão de Alimentos , Peixes , Cadeia Alimentar , Nylons/análise , Polietileno/análise , Polietilenotereftalatos/análise , Polimetil Metacrilato/análise , Polipropilenos/análise , Cloreto de Polivinila/análise , Rios/química , Alimentos Marinhos
10.
Ugeskr Laeger ; 179(30)2017 Jul 24.
Artigo em Dinamarquês | MEDLINE | ID: mdl-28789768

RESUMO

An orthopaedic surgeon with no history of lung disease developed cough and dyspnoea. The patient was diagnosed with asthma by spirometry and bronchial provocation test with methacholine. A clear correlation between symptoms and work was established meriting a referral to a centre for occupational health. The patient was diagnosed with work-related disease, which was recognized by the industrial injury board. The cause was methyl methacrylate, a known airway irritant, which is an important component of bone cement. Previously, no cases of work-related asthma in orthopaedic surgeons have been reported.


Assuntos
Asma Ocupacional , Cimentos Ósseos/efeitos adversos , Cirurgiões Ortopédicos , Polimetil Metacrilato/efeitos adversos , Asma Ocupacional/induzido quimicamente , Asma Ocupacional/diagnóstico , Cimentos Ósseos/química , Testes de Provocação Brônquica , Humanos , Masculino , Exposição Ocupacional/efeitos adversos , Pico do Fluxo Expiratório , Polimetil Metacrilato/análise , Espirometria
11.
J Mech Behav Biomed Mater ; 75: 175-179, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28734259

RESUMO

Occlusal splints to treat bruxism are commonly made from polymethylmethacrylate (PMMA) in a manual workflow (powder-liquid technique). Today digitalization allows a machine-based manufacturing in subtractive (milling) and additive (printing) means using industrial-made PMMA or comparable resins. An in-vitro study should assess the surface finish and screen the wear resistance of conventional and industrial materials. Therefore, a total of 30 specimens made from conventionally PMMA (group C; powder-liquid, Palapress), polycarbonate ingots (group S; innoBlanc splint plus), and light-curing resin (group A; VarseoWax splint) were polished to examine the surface roughness (Ra) by profilometry and further analyzed by SEM. The specimens were loaded with a steatite ball moving 5000 times along 1cm with 5N of surface pressure under constant wetting (artificial saliva). The total height of profile (Pt) was calculated by further profilometry of the specimens. All specimen showed initially comparable Ra values ranging between 0.06 and 0.05µm (SD = 0.01) after polishing. SEM investigations revealed no visual cues for scratches or irregularities in any group. After abrasion test, the comparison of the wear depths, revealed mean Pt values of 111.4µm (SD = 18.5) in C, 85.7µm (SD = 21.5) in S, and 99.1µm (SD = 21.5) in A, whereas the mean of S was statistically different from C (p = 0.025). No signs of abrasion were found on the steatite balls. All materials showed comparable polished surfaces and a similar scale of wear. It remains questionable if the detected statistical differences are of clinical relevance, but indicates the need for tests of novel materials, especially in additive manufacturing.


Assuntos
Teste de Materiais , Aparelhos Ortodônticos Removíveis , Polimetil Metacrilato/análise , Contenções , Bruxismo , Humanos , Propriedades de Superfície
12.
Int J Hyg Environ Health ; 220(7): 1190-1194, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28711304

RESUMO

On June 1st, 2007 the European regulation on Registration, Evaluation and Restriction of Chemical substances (REACH) came into force. Aim of the regulation is safe use of chemicals for humans and for the environment. The core element of REACH is chemical safety assessment of chemicals and communication of health and safety hazards and risk management measures throughout the supply chain. Extended Safety Data Sheets (Ext-SDS) are the primary carriers of health and safety information. The aim of our project was to find out whether the actual exposure to methyl methacrylate (MMA) during the application of polymethylmethacrylate (PMMA) in floor coatings as assessed in the chemical safety assessment, reflect the exposure situations as observed in the Dutch building practice. Use of PMMA flooring and typical exposure situations during application were discussed with twelve representatives of floor laying companies. Representative situations for exposure measurements were designated on the basis of this inventory. Exposure to MMA was measured in the breathing zone of the workers at four construction sites, 14 full shift samples and 14 task based samples were taken by personal air sampling. The task-based samples were compared with estimates from the Targeted Risk Assessment Tool (v3.1) of the European Centre for Ecotoxicology and Toxicology of Chemicals (ECETOC-TRA) as supplied in the safety assessment from the manufacturer. For task-based measurements, in 12 out of 14 (86%) air samples measured exposure was higher than estimated exposure. Recalculation with a lower ventilation rate (50% instead of 80%) together with a higher temperature during mixing (40°C instead of 20°C) in comparison with the CSR, reduced the number of underestimated exposures to 10 (71%) samples. Estimation with the EMKG-EXPO-Tool resulted in unsafe exposure situations for all scenarios, which is in accordance with the measurement outcomes. In indoor situations, 5 out of 8 full shift exposures (62%) to MMA were higher than the Dutch occupational exposure limit of 205mg/m3 (8h TWA), which equals the DNEL. For semi-enclosed situations this was 1 out of 6 (17%). Exposures varied from 31 to 367mg/m3. The results emphasize that ECETOC-TRA exposure estimates in poorly controlled situations need better underpinning.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/análise , Exposição Ocupacional/análise , Polimetil Metacrilato/análise , Poluição do Ar em Ambientes Fechados/análise , Segurança Química/legislação & jurisprudência , Segurança Química/métodos , Monitoramento Ambiental/métodos , Pisos e Cobertura de Pisos , Humanos , Exposição por Inalação/análise , Concentração Máxima Permitida , Países Baixos , Medição de Risco
13.
Waste Manag Res ; 35(3): 294-300, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28219298

RESUMO

Microwave-assisted potassium permanganate modification (MPPM) was used for the flotation separation of polycarbonate (PC) from polyvinyl chloride (PVC) and polymethylmethacrylate (PMMA) waste plastics. The separation process was optimized by investigating the potassium permanganate concentration, treatment time, flotation time and frother concentration. MPPM selectively reduced the flotation recovery of PC. The optimum conditions were determined to be: potassium permanganate concentration, 2 mM/L; treatment time, 1 min; frother concentration, 17.57 g/L; and flotation time, 1 min. PC was efficiently separated from PVC and PMMA under the optimum conditions. The purity of the separated PC was 97.71%. The purity and recovery of PVC and PMMA were both >95%. The modification mechanism was investigated using the water contact angles, Fourier transform infrared spectrometry and scanning electron microscopy. This work provides technical insights into the industrial recycling of waste plastics.


Assuntos
Micro-Ondas , Plásticos/análise , Permanganato de Potássio/química , Eliminação de Resíduos/métodos , Resíduos Sólidos/análise , Cimento de Policarboxilato/análise , Polimetil Metacrilato/análise , Cloreto de Polivinila/análise , Reciclagem , Gerenciamento de Resíduos
14.
J Mech Behav Biomed Mater ; 65: 29-41, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27552597

RESUMO

Osteoporotic fractures poses one of the most problematic health issues that affects millions of people by weakening their bones (Osteoporosis). Polymethylmethacrylate (PMMA) cement is usually used to augment the bone and stabilize the fractures. Despite the benefit of using PMMA, it might cause a leakage where the cement undesirably access the surrounding tissues or vessels and lead to a serious complications. Consequently, it is important to study the leakage phenomenon and associated geometric and operation interactions. Although the experimental leakage models have been reported in many studies, a representative numerical leakage model is not exist. Therefore, the objectives of the present paper are to: (a) to develop and validate a representative numerical leakage model; and (b) to investigate numerically and analytically the importance of the rheological parameters (viscosity and relaxation time) on the cement flow to reduce the risk of leakage. ANSYS Polyflow was utilized to implement a 2D numerical leakage model to study the interaction of complex rheological parameters of the cement with the operational and geometrical structure of the representative porous media. In this model, the cement (represented by the upper-convected Maxwell model) flows from the entrance (tip of an 8 gauge cannula) through a porous media with a leakage path (blood vessels) toward the output (Bottom side). The verified and validated numerical leakage model showed the importance of the elastic and viscous part of the cement to control the uniformity of the distributed cement and augmentation pressure, respectively. Moreover, increasing the flow rate can lead to reduce the risk of leakage since the elastic effect will increase. Geometrical parameters of the porous media has a minor effect on changing the elasticity and subsequently on the uniformity of the distributed cement. In conclusion, Cement rheological parameters are found to be the most influential parameters to reduce the risk of leakage by controlling the uniformity of the distributed cement and the augmentation pressure.


Assuntos
Cimentos Ósseos/análise , Osteoporose/terapia , Polimetil Metacrilato/análise , Substâncias Viscoelásticas/análise , Humanos , Modelos Teóricos , Porosidade , Reologia
15.
Biomed Res Int ; 2016: 7901562, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27812530

RESUMO

Polymethylmethacrylate (PMMA) bone cement is a popular bone void filler for vertebroplasty. However, the use of PMMA has some drawbacks, including the material's excessive stiffness, exothermic polymerization, and short handling time. This study aimed to create an ideal modified bone cement to solve the above-mentioned problems. Modified bone cements were prepared by combining PMMA with three different volume fractions of castor oil (5%, 10%, and 15%). The peak polymerization temperatures, times to achieve the peak polymerization temperature, porosities, densities, modulus and maximum compression strengths of standard (without castor oil), and modified cements were investigated following storage at ambient temperature (22°C) or under precooling conditions (3°C). Six specimens were tested in each group of the aforementioned parameters. Increasing castor oil content and precooling treatment effectively decreased the peak polymerization temperatures and increased the duration to achieve the peak polymerization temperature (P < 0.05). Furthermore, the mechanical properties of the material, including density, modulus, and maximum compression strength, decreased with increasing castor oil content. However, preparation temperature (room temperature versus precooling) had no significant effect (P > 0.05) on these mechanical properties. In conclusion, the addition of castor oil to PMMA followed by precooling created an ideal modified bone cement with a low modulus, low polymerization temperature, and long handling time, enhancing its applicability and safety for vertebroplasty.


Assuntos
Cimentos Ósseos/síntese química , Óleo de Rícino/química , Polimetil Metacrilato/química , Vertebroplastia/métodos , Adesividade , Cimentos Ósseos/análise , Força Compressiva , Módulo de Elasticidade , Dureza , Teste de Materiais , Polímeros/síntese química , Polimetil Metacrilato/análise , Estresse Mecânico , Temperatura , Resistência à Tração , Fatores de Tempo
16.
J Pharm Biomed Anal ; 117: 405-12, 2016 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-26440288

RESUMO

Praziquantel (PZQ) is the drug recommended by the World Health Organization for treatment of schistosomiasis. However, the treatment of children with PZQ tablets is complicated due to difficulties to adapt the dose and the extremely bitter taste of PZQ. For this reason, poly (methyl methacrylate) nanoparticles loaded with Praziquantel (PZQ-NP) were developed for preparation of a new formulation to be used in the suspension form. For this reason, the main aim of the present study was to evaluate the pharmacokinetic (PK) profile of PZQ-NP, through HPLC-MS/MS assays. Analyses were performed with an Omnisphere C18 column (5.0 µm×4.6 mm×150.0 mm), using a mixture of an aqueous solution containing 0.1 wt% of formic acid and methanol (15:85-v/v) as the mobile phase at a flow rate of 0.800mL/min. Detection was performed with a hybrid linear ion-trap triple quadrupole mass spectrometer with multiple reactions monitoring in positive ion mode via electrospray ionization. The monitored transitions were m/z 313.18>203.10 for PZQ and m/z 285.31>193.00 for the Internal Standard. The method was validated with the quantification limit of 1.00 ng/mL, requiring samples of 25 µL for analyses. Analytic responses were calibrated with known concentration data, leading to correlation coefficients (r) higher than 0.99. Validation performed with rat plasma showed that PZQ was stable for at least 10 months when stored below -70 °C (long-term stability), for at least 17 h when stored at room temperature (RT, 22 °C) (short-term stability), for at least 47 h when stored at room temperature in auto-sampler vials (post-preparative stability) and for at least 8 successive freeze/thaw cycles at -70 °C. For PK assays, Wistar rats, weighing between 200 and 300 g were used. Blood samples were collected from 0 to 24 h after oral administration of single doses of 60 mg/kg of PZQ-NP or raw PZQ (for the control group). PZQ was extracted from plasma by liquid-liquid extraction with terc-butyl methyl ether. The values obtained for maximum concentration (C(max)) and area under curve (AUC) for the PZQ-NP group were about 3 times smaller than the respective values obtained for the control group. However, the time for achieving maximum concentration (T(max)), the elimination constant (Ke) and the half-life time of elimination (T(½ß)) were not statistically different. These results suggest that PZQ absorption is probably the rate-limiting step for obtainment of better PK parameters for PZQ-NP. Thus, further studies are needed to understand both the PZQ-NP absorption mechanisms and the drug diffusion process through the polymer matrix in vivo, in order to improve the PZQ-NP release profile.


Assuntos
Nanopartículas/metabolismo , Polimetil Metacrilato/farmacocinética , Praziquantel/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Feminino , Nanopartículas/análise , Polimetil Metacrilato/análise , Praziquantel/análise , Ratos , Ratos Wistar
17.
Arq. bras. med. vet. zootec ; 67(3): 671-678, May-Jun/2015. graf
Artigo em Inglês | LILACS | ID: lil-753930

RESUMO

Tibiotarsal fractures are common in birds because in most birds this is the longest, most exposed bone in the leg. Transverse fractures are most common and rotational and shear forces must be stabilized in order to achieve good bone regeneration. A 230g male Slender-billed Parakeet or Choroy parakeet (Enicognathus leptorhynchus), with more than five years of age, was received with non-weight bearing lameness with 24 hours duration. X-rays were taken, and these revealed a closed, complete, non-comminuted transverse fracture of the distal diaphysis of the left tibiotarsal bone. Fixation was planned with 10-minute fast-setting epoxy putty. In order to assess the temperature of polymerization of the epoxy dough and the possibility of heat-bone necrosis, the temperature was recorded every 30 seconds for 12 minutes with three different amounts of the epoxy material in an ex vivo test. The temperature of the pieces reached a peak of 50-60ºC, where the highest peak corresponds to the highest amount of material. When approximately 6g of putty were used, the peak temperature reached only 51ºC. This peak changed to 58ºC when 4 times more epoxy was mixed and measured. If the temperature of the pins inserted in the bone exceeds 70ºC, bone necrosis could occur. In light of these results, the fracture was treated with 6 g of epoxy putty that was allowed to polymerize over a 1A 2/2 external skeletal fixation, with 1-mm pins bent at 90º and joined together with cerclage wire. At 6 weeks after surgery the bird had formed a good primary bone callus, and the external fixators were therefore removed. With this approach a satisfactory recovery of the patient was achieved with normal use of the affected limb.


Fraturas tibiotársicas são comuns em aves, pois, na maioria das aves, o tibiotarso é o osso mais longo e exposto nesses animais. Fraturas transversais são mais comuns, sendo que as forças de rotação e cisalhamento devem ser estabilizadas de modo a alcançar uma boa regeneração óssea. Um periquito macho do tipo psitacídeo de 230g, com mais de 5 anos, foi recebido apresentando claudicação a 24 horas não devido a transferência de carga. Os exames radiográficos revelaram uma fratura fechada completa, não triturada, transversal de diáfise distal do osso esquerdo tibiotársico. A fixação foi feita com massa epóxi de endurecimento rápido (10 minutos). A fim de avaliar a temperatura de polimerização da massa epóxi e a possibilidade de necrose desses ossos, a temperatura foi registrada a cada 30 segundos durante 12 minutos, com três quantidades diferentes de epóxi em teste in vivo. A temperatura das amostras fragmentadas atingiu um pico de 50-60ºC, em que o pico mais elevado corresponde à maior quantidade de massa epóxi. Quando foram utilizados cerca de 6g de massa de vidraceiro, o pico de temperatura foi de apenas 51ºC. Esse pico foi alterado para 58ºC quando se aumentou a quantidade de massa epóxi quatro vezes. Se a temperatura dos pinos inseridos no osso for superior a 70ºC, pode ocorrer necrose do osso. À luz desses resultados, a fratura foi tratada com 6g de massa epóxi deixada polimerizar sobre uma fixação externa, em configurações 1A 2/2 usando pinos de 1mm, dobrados em 90º e unidos com fios de cerclage. Após 6 semanas da cirurgia, o pássaro tinha formado um calo ósseo primário, sendo os fixadores externos removidos. Com essa abordagem, conclui-se que houve a restauração das funções normais do membro e total recuperação da ave.


Assuntos
Animais , Ossos do Tarso/lesões , Periquitos/lesões , Polimetil Metacrilato/análise , Fixação de Fratura/veterinária , Fixadores Externos/veterinária
18.
Mater Sci Eng C Mater Biol Appl ; 51: 107-16, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25842114

RESUMO

This work presents the rheological assessment of poly(methyl methacrylate) (PMMA) polymers synthesized in a dedicated pilot-scale plant. This material is to be used for the construction of scaffolds via Rapid Prototyping (RP). The polymers were prepared to match the physical and biological properties required for medical applications. Differential Scanning Calorimetry (DSC) and Size Exclusion Chromatography (SEC) measurements verified that the synthesized polymers were atactic, amorphous and linear in chains. Rheological properties such as viscosity, storage and loss modulus, beyond the loss factor, and creep and recovery were measured in a plate-plate sensor within the viscoelastic linear region. The results showed the relevant influence of the molecular weight on the viscosity and elasticity of the material, and how, as the molecular weight increases, the viscoelastic properties are getting closer to those of human bone. This article demonstrates that by using the implemented methodology it is possible to synthesize a polymer, with properties comparable to commercially-available PMMA.


Assuntos
Materiais Biocompatíveis/síntese química , Cimentos Ósseos/síntese química , Polimetil Metacrilato/síntese química , Materiais Biocompatíveis/análise , Cimentos Ósseos/análise , Módulo de Elasticidade , Temperatura Alta , Teste de Materiais , Peso Molecular , Projetos Piloto , Polimetil Metacrilato/análise , Pressão , Viscosidade
19.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 59(2): 122-128, mar.-abr. 2015. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-133875

RESUMO

Objetivo: El objetivo de este estudio es comparar la biocompatibilidad y efecto sobre osteoblastos de polimetilmetacrilato solo y PMMA al que se ha añadido, hidroxiapatita en concentraciones del 5, 10, 15 y 20%, no superando nunca esta cifra del 20%, dado que si se supera esta cifra pueden verse alteradas las propiedades biomecánicas del PMMA. Material y métodos: Estudio experimental que consiste en el estudio de la adhesividad, diferenciación y muerte celular sobre discos de PMMA y composite PMMA/HA a diferentes concentraciones. Resultados: Los composites al 15 y especialmente al 20% presentaron mejor respuesta osteoblástica, mayores marcadores de actividad y menores marcadores de apoptosis. En las imágenes de microcopía electrónica se aprecia una mayor adhesión celular (AU)


Objective: The purpose of this study is to compare the biocompatibility and the effect in osteoblasts of polymethyl methacrylate alone, and mixed with hydroxyapatite in different concentrations of 5, 10, 15 and 20%, without exceeding 20%, as it can alter mechanical properties of the composite. Material and methods: Experimental study comparing osteoblast response to Polymethyl methacrylate alone and with hydroxyapatite in different concentrations. Results: Composites at 15 and 20% obtained better osteoblast response, with higher osteoblastic activity markers, and lower apoptosis markers. Electron microscopy images show improved adhesion of osteoblasts (AU)


Assuntos
Humanos , Osteoblastos/fisiologia , Cimentos Ósseos/uso terapêutico , Fraturas da Coluna Vertebral/cirurgia , Fixação Interna de Fraturas/métodos , Osseointegração/fisiologia , Adesividade , Hidroxiapatitas/análise , Polimetil Metacrilato/análise , Resultado do Tratamento
20.
J Arthroplasty ; 30(8): 1464-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25795235

RESUMO

As the use of cement remains prevalent in orthopedic surgery, so do concerns over the safety of its active ingredient, methyl methacrylate (MMA). The Occupational Health and Safety Agency (OSHA) limits the airborne exposure to 100 parts per million (ppm) averaged over an 8 hour period. We measured MMA exposure to operating room personnel during simulated total hip arthroplasty (THA), antibiotic bead fabrication and simulated spill of MMA. Cumulative and peak exposures during simulated THA and antibiotic bead fabrication did not exceed OSHA limits of 100ppm. Vacuum mixing and greater distance from the vapor source reduced measured MMA exposure. Spilled MMA led to prolonged and elevated MMA levels. MMA levels returned to a negligible level in all scenarios by 20 minutes after mixing.


Assuntos
Poluentes Ocupacionais do Ar/análise , Cimentos Ósseos/análise , Monitoramento Ambiental , Exposição por Inalação , Exposição Ocupacional , Polimetil Metacrilato/análise , Ar/análise , Artroplastia de Quadril , Humanos , Salas Cirúrgicas , Volatilização
SELEÇÃO DE REFERÊNCIAS